Ads

Friday, March 6, 2015

Jointed Plain Concrete Pavement

Jointed plain concrete pavement (JPCP, Figure 1) uses contraction joints to control cracking and does not use any reinforcing steel. Transverse joint spacing is selected such that temperature and moisture stresses do not produce intermediate cracking between joints. This typically results in a spacing no longer than about 6.1 m (20 ft.). Dowel bars are typically used at transverse joints to assist in load transferTie bars are typically used at longitudinal joints.


Properties

Crack Control

Contraction joints, both transverse and longitudinal

Joint Spacing

Typically between 3.7 m (12 ft.) and 6.1 m (20 ft.). Due to the nature of concrete, slabs longer than about 6.1 m (20 ft.) will usually crack in the middle. Depending upon environment and materials slabs shorter than this may also crack in the middle.

Reinforcing Steel

None.

Load Transfer

Aggregate interlock and dowel bars. For low-volume roads aggregate interlock is often adequate. However, high-volume roads generally require dowel bars in each transverse joint to prevent excessive faulting.

Other Info

A majority of U.S. State DOTs build JPCP because of its simplicity and proven performance.


- Source at: http://www.pavementinteractive.org/article/jointed-plain-concrete-pavement